Page 134 - 69_01
P. 134
D. FERREIRA Y COLS. ANAL. REAL ACAD. NAL. FARM
RESULTS AND DISCUSSION
The microcapsules loading of naproxen was theoretically calcu-
lated and the intended value was 22.2%. The naproxen content of the
microcapsules varied from 14.8% to 15.3 % for microcapsules containing
polymer. However, when the microcapsules included plasticizers the
naproxen content was between 15.9% and 16.8%, as it can be seen in
Table 2.
Table 2. Naproxen loading of the microcapsules.
Formulations Loading (%)
A 14.8
B 15.2
C 14.8
D 15.3
E 14.9
F 16.8
G 16.1
H 15.9