Page 134 - 69_01
P. 134

D. FERREIRA Y COLS.                ANAL. REAL ACAD. NAL. FARM

         RESULTS AND DISCUSSION

         The microcapsules loading of naproxen was theoretically calcu-
lated and the intended value was 22.2%. The naproxen content of the
microcapsules varied from 14.8% to 15.3 % for microcapsules containing
polymer. However, when the microcapsules included plasticizers the
naproxen content was between 15.9% and 16.8%, as it can be seen in
Table 2.

                     Table 2. Naproxen loading of the microcapsules.

                     Formulations  Loading (%)

                     A 14.8

                     B 15.2

                     C 14.8

                     D 15.3

                     E 14.9

                     F 16.8

                     G 16.1

                     H 15.9

140